A.control inlet air temperature
B.control inlet air volume
C.maintain relative humidity at 15%
D.restore conditioned air temperature to a comfortable level
您可能感興趣的試卷
你可能感興趣的試題
A.bilge well connected to that valve, plus the second bilge well being pumped will be completely emptied
B.bilge system will lose vacuum and prevent the other bilges from being pumped out
C.bilge well aft connected to that valve will siphon its contents to the forward bilge wells
D.discharge pressure will be too high
A.bypass exhaust gas at high loads to prevent excessive back pressure
B.bypass a portion of the exhaust gas at peak loads for better efficiency
C.recycle exhaust gas to the turbocharger
D.minimize moisture condensation in the boiler gas passages at low loads
A.Correct the cause of the scoring and repair the sleeve or replace with a new one
B.Reassemble the unit and provide more water leak off for proper lubrication
C.Check for parallel alignment of the sleeve radial faces to the sleeve bores
D.Reassemble the unit and adjust the governor to obtain a slower speed
A.Copper
B.Copper and carbon
C.Carbon
D.Bronze
A.Chilled water system supply temperature
B.Chilled water system return temperature
C.Compressor discharge temperature
D.Compressor suction pressure
最新試題
To proceed to the assistance of a ship in distress is()
The flash point of a residual fuel oil should be used to determine the highest temperature to which oil may be heated()
The cetane rating of diesel fuel is an indication of the ()
“Insufficiency of manning or insufficiency of certification of seafarers” is an identification of a()
If separating effect is not good, which measure should be taken ()
Refrigerant entering the compressor of a refrigeration system should be in which of the following conditions?()
When does auxiliary burner of incinerator put into operation? ()Ⅰ. start incinerator when it is coldⅡ. the sludge for dealing with is littleⅢ. the sludge for dealing with is largeⅣ. the water and impurity in sludge are too muchⅤ. the temperature in incinerator is lowⅥ. dealing with little solid rubbish
Diesel engine air start system check valves are opened by ()
As soon as a diesel engine has started, which of the listed engine operating parameters should be checked FIRST?()
Under MARPOL Code the ship to which it applies has to carry ()